ES 57 SPECIFICATION
Luminaire
will be of high-energy efficiency to be used on 230V
AC system.
Compliance
with Standards:
The
Luminaire must comply with the following standards:
SANS 60598-1:2007 “Luminaires; General requirements
and tests”
IP
66 rating
The
Manufacturer must be certified to ISO 9001 as well as
ISO 14000
Lamp
Specification:
Lamp used will be a 57 watt Compact Fluorescent type
with an output of 4300 lumen.
The Colour rendering of the lamp (Ra) will be better
than 81.
The
rated lamp life will be at least 12 000 hours if switched
once every 3 hours and typically 20 000 hours if switched
once every 24 hours.
The
lamp output will be within 15% of rated value over lamp
life.
The
lamp will re-strike immediately at power restoration
following a power failure or voltage dips.
Ballast
Specification
The
luminaire will be fitted with electronic ballast rated
230 volt operating on 50/60 Hz.
The
line current will be 0.26 Amps
The
ballast should be able to operate with the lamp striking
within the temperature range from -30C to 75C.
The
ballast should have an expected life of 100 000 hours
Ballast
shall be Programmed Rapid Start.
Ballast shall incorporate lamp shutdown circuitry for
end of lamp life protection.
Ballast shall allow for re-lamping without the need
to cycle power.
Ballasts
shall operate from 50/60 Hz input source with no damage
to the ballast.
Ballast shall be of metal can construction to meet all
plenum requirements and to eliminate the need for extra
grounding wires
Ballasts
shall be a high frequency electronic type, and operate
lamps at a frequency above 40 kHz to minimize interference
Lamp Current Crest Factor (ratio of peak to RMS current)
shall be 1.7 or less in accordance with lamp manufacturer
recommendation and ANSI C82.11-1993.
Ballasts shall tolerate operation in ambient temperatures
up to 55°C without damage.
Ballasts
shall have a maximum case temperature test point of
75°C printed on the label for easy fixture testing and
trouble shooting.
Ballast shall have a maximum case temperature rise of
15°C.
Ballasts shall comply with FCC Part 18 Non-Consumer
Equipment for EMI (power line conducted) and RFI (Radiated).
Ballasts shall provide transient immunity as recommended
by ANSI C62.41-2002.
Ballasts shall operate lamps with no visible flicker
(<3% flicker index).
Ballasts
shall tolerate sustained open and short circuit output
conditions without damage.
Ballasts
shall be listed, Class P, Type 1 Outdoor, and CSA certified
and unless noted otherwise, approved for use in hazardous
locations (Type HL).
Input current Total Harmonic Distortion shall not exceed
10%.
Ballasts
shall have a Power Factor greater than 0.99
The manufacturer shall provide written warranty against
defects in material or workmanship, including replacement,
for three years from date of manufacture.
Manufacturer
shall have been manufacturing electronic ballasts for
at least fifteen years.
Ballast
shall be manufactured in an ISO 9001 Certified Facility.
General Luminaire Specification
The
luminaire shall be a full cut-off type resulting in
no spill light.
The
luminaire shall be of the type to accommodate a standard
42mm spigot.
The
luminaire shall be fitted with tools free terminals
for the connection of the live, neutral and earth connections.
It
shall be fitted with an isobaric seal between compartments
to prevent pressure build up between the IP66 compartments.
The
fitting shall be designed with an internal daylight
switch and internal 500mA circuit breaker as optional
extras.
The
luminaire shall have a maximum weight of 5kg.
The
reflector shall be of a multifaceted type and the whole
inner area of the luminaire housing must be an integral
reflector with a minimum reflectance of 92%.
The
luminaire shall be fitted with automatic power disconnection
to the lamp terminals on opening.
5
stainless steel clips will secure the lid of the luminaire.
All
metalwork of the luminaire will be stainless steel.
The housing, base and bulkhead will be manufactured
from a mineral filled UV stabilized Polypropylene while
the reflector and lamp holder shall be of polycarbonate.
The
lens must be constructed of an acrylic polymer with
lifelong guarantee against dis- coloration.
The
luminaire must be about 695 mm long, 400mm wide and
170mm deep.
Light
Output Requirement
The
luminous intensity in the vertical plane 0-180 should
peak at 67.5 up from vertical at a value of at least
450 cd/klm.
The
maximum luminous intensity shall be at the vertical
plane of 15-165 and shall be at least 530 cd/klm at
an angle of about 68 up from vertical.
Please